Personal tools
You are here: Home EPI STAMIC

STAMIC

Male, 15 y.o., with epilepsy due to right frontal lobe tumor

Duration of the recordings: 20'28"
Number of seizures included: 0
Age at recording: 15
Age at surgery: 15
Maximal interictal period included: 20'28"
Number of inter-ictal events: 5
Epileptogenic structures marked by epileptologis
STAMIC
Scans of 3 MRI sections with location of foci
STAMIC

14 y.o. male, with generalized seizures since Oct 2007, which occurred once in a month.

EEG revealed minor abnormalities - some dispersed spiking and slow waves

MRI showed parasagital tumor within structures of right frontal lobe in anterior part.

He was operated on Apr 2008 - lesionectomy with tumor removal and MST Morrell section within medial frontal gyrus. Seizure free since than.

Pathology DNT, WHO GI

 


EEG hardware used: Medelec Profile Videometry System
Kind of electrodes: Ag/AgCl 10mm
Hardware reference: bipolar
Sampling rate: 256 Hz
Hardware filters: 0.5-70 Hz
Software filters: 50 Hz notch
Other hardware hooked up: none
Patient state during recording: resting

MRI hardware: SIEMENS Sonata 1.5T
Image processing prior to archival: none